Header Logo

Connection

Ji Chen to Hot Temperature

This is a "connection" page, showing publications Ji Chen has written about Hot Temperature.
Connection Strength

4.247
  1. RF-induced heating reduction by minimizing the external portion of the partially in and partially out medical devices under MRI at 1.5?T. Magn Reson Med. 2025 May; 93(5):2108-2122.
    View in: PubMed
    Score: 0.920
  2. Reducing MRI RF-induced heating for the external fixation using capacitive structures. Phys Med Biol. 2020 08 11; 65(15):155017.
    View in: PubMed
    Score: 0.683
  3. Evaluation of MRI RF electromagnetic field induced heating near leads of cochlear implants. Phys Med Biol. 2018 07 06; 63(13):135020.
    View in: PubMed
    Score: 0.590
  4. Effect of insulating layer material on RF-induced heating for external fixation system in 1.5 T MRI system. Electromagn Biol Med. 2014 Sep; 33(3):223-7.
    View in: PubMed
    Score: 0.416
  5. RF-induced heating for active implantable medical devices in dual parallel leads configurations at 1.5 T MRI. Magn Reson Med. 2023 08; 90(2):686-698.
    View in: PubMed
    Score: 0.205
  6. A technique for the reduction of RF-induced heating of active implantable medical devices during MRI. Magn Reson Med. 2022 01; 87(1):349-364.
    View in: PubMed
    Score: 0.183
  7. Body-loop related MRI radiofrequency-induced heating hazards: Observations, characterizations, and recommendations. Magn Reson Med. 2022 01; 87(1):337-348.
    View in: PubMed
    Score: 0.183
  8. Effects of patient orientations, landmark positions, and device positions on the MRI RF-induced heating for modular external fixation devices. Magn Reson Med. 2021 03; 85(3):1669-1680.
    View in: PubMed
    Score: 0.172
  9. Wire-based sternal closure: MRI-related heating at 1.5 T/64 MHz and 3 T/128 MHz based on simulation and experimental phantom study. Magn Reson Med. 2020 03; 83(3):1055-1065.
    View in: PubMed
    Score: 0.160
  10. Computational and experimental investigation of RF-induced heating for multiple orthopedic implants. Magn Reson Med. 2019 11; 82(5):1848-1858.
    View in: PubMed
    Score: 0.157
  11. On the development of equivalent medium for active implantable device radiofrequency safety assessment. Magn Reson Med. 2019 09; 82(3):1164-1176.
    View in: PubMed
    Score: 0.157
  12. Numerical evaluation of RF-induced heating for various esophageal stent designs under MRI 1.5 Tesla system. Electromagn Biol Med. 2017; 36(4):379-386.
    View in: PubMed
    Score: 0.141
  13. Numerical investigations of MRI RF field induced heating for external fixation devices. Biomed Eng Online. 2013 Feb 09; 12:12.
    View in: PubMed
    Score: 0.101
  14. Computational and experimental studies of an orthopedic implant: MRI-related heating at 1.5-T/64-MHz and 3-T/128-MHz. J Magn Reson Imaging. 2013 Feb; 37(2):491-7.
    View in: PubMed
    Score: 0.098
  15. MRI Evaluation of an Atrial-Anchored Transcatheter Mitral Valve Replacement Implant. AJR Am J Roentgenol. 2020 Mar; 214(3):524-528.
    View in: PubMed
    Score: 0.041
  16. Evaluation of MRI Issues for a New Wirelessly Powered, Spinal Cord Stimulation Lead With Receiver. AJR Am J Roentgenol. 2020 Feb; 214(2):406-412.
    View in: PubMed
    Score: 0.041
Connection Strength

The connection strength for concepts is the sum of the scores for each matching publication.